Published July 1991 | Version v1
Journal article

Radon measurements of some cities with CSR detectors

  • 1. Institute of Environmental Protection, Wuhan, HB (China)

Description

The indoor and outdoor radon measurements in Haerbin and Yanan have been made with CSR (China Shanghai Resin) detectors. At main measuring sites the balloon method has been used to measure the latent energy of daughters and the equilibrium factor. The results by the two methods have been compared and analysed. The measurements with CSR detectors indicate that the indoor radon concentration ranges from 16 to 144 Bq/m3 with an average of 73 Bq/m3 in Haerbin, and from 13 to 78 Bq/m3 with an average of 35 Bq/m3 in Yanan. The results are compared with those with the balloon method, showing that the two methods are consistent within an error of 40%

Additional details

Publishing Information

Journal Title
Nuclear Techniques
Journal Volume
14
Journal Issue
7
Series
Nucl. Tech.
Journal Page Range
400-403
ISSN
0253-3219
CODEN
NUTED