Method for determinining the charged particle momenta under the ''Hyperon'' set-up conditions

  • 1. Joint Inst. for Nuclear Research, Dubna (USSR). Lab. of Nuclear Problems
  • 2. Bylgarska Akademiya na Naukite, Sofia. Inst. za Yadrena Izsledvaniya i Yadrena Energetika

Description

The method and developed on its base programmes for the determination of the charge particles momenta under the conditions of the ''Hyperon'' set-up are described. The magnetic field card of the spectrometric electromagnet which contains 415000 values, is substituted by a set of 2500 factors of the Chebyshev polynoms used for the reconstruction of the charged particles mometa. Due to the described method the momentum determination error is 0.1-0.2 per cent. The average reconstruction time of the single particle momenta does not exceed 0.1 s for the EC 1060 computer

Availability note (English)

MF available from INIS under the Report Number.

Files

15014220.pdf

Files (246.1 kB)

Name Size Download all
md5:346b9ea1f976c7a9953260dd2aa85c31
246.1 kB Preview Download

System files (34.3 kB)

Name Size Download all

Additional details

Additional titles

Original title (Russian)
Методика определения импульсов заряженных частиц в условиях установки ''Гиперонь

Publishing Information

Imprint Pagination
10 p.
Report number
JINR-R--1-83-390

Optional Information

Notes
10 refs.; 3 figs.; 1 tab.