Published March 14, 1972
| Version v1
Report
Restricted
Open channel plenum model hydraulic development test: flared inlet lines
Description
The test results are presented of the hydraulic studies on the SPF open channel Inlet Plenum Model with flared inlet lines. An evaluation was made of the effectiveness of 4 and 5-vane diffusers in 2 x 3 straight flared inlets, 5-vane diffusers in 2 x 3 curved flared inlets and 5-vane diffusers in 2 x 4 straight flared inlets. The 5-vane diffusers in 2 x 3 straight flared inlets provided the flattest pressure profiles at the grid plate and were recommended for incorporation into the plenum design. (U.S.)
Availability note (English)
MF available from INIS under the Report Number.
Files
Additional details
Additional titles
- Augmented title (English)
- Space power reactors
Publishing Information
- Imprint Pagination
- 43 p.
- Report number
- TR--653-210-002
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 6215709
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- CONFIGURATION; HYDRAULICS; LIQUID FLOW; PRIMARY COOLANT CIRCUITS; REACTOR CORES; SPACE POWER REACTORS; TESTING
- Descriptors DEC
- FLUID FLOW; MOBILE REACTORS; POWER REACTORS; REACTOR COMPONENTS; REACTOR COOLING SYSTEMS; REACTORS