Published December 1975 | Version v1
Report

Beam pipe for polarization experiments

Creators

Description

The design of a polarized beam vacuum chamber for the PEP storage rings is discussed, including the cooling system, the radiation absorber, and chamber dimensions. The chamber has a complicated shape and is designed to absorb the synchrotron radiation coming from the polarized magnetic fields and to cover the energy range from 5 to 15 GeV/c

Additional details

Publishing Information

Imprint Title
Proceedings of the 1975 PEP summer study, July 28--August 20, 1975, Berkeley, California
Imprint Pagination
p. 23-25.
Report number
LBL--4800

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
7273492
Subject category
S43: PARTICLE ACCELERATORS;
Descriptors DEI
COOLING SYSTEMS; DIMENSIONS; ENERGY TRANSFER; PEP STORAGE RINGS; POLARIZED BEAMS; SPECIFICATIONS; SYNCHROTRON RADIATION; VACUUM SYSTEMS
Descriptors DEC
BEAMS; BREMSSTRAHLUNG; ELECTROMAGNETIC RADIATION; RADIATIONS; STORAGE RINGS