Relationship between Personal Dosemeters Reading and Human Doses
- 1. National Atomic Energy Agency, Jakarta (Indonesia), Center for Standardization and Radiation Safety Research
Description
The relationship between personal dosemeter reading and the effective male dose (equivalent), the effect of skin-dosemeter distance and the effect of angular responce of dosemeters, were studied using a computational model developed in JAERI and a realistic body phantom. The relationship was calculated for five locations of dosemeters worn at the skin surface of the trunk. The calculations showed that the dosemeters at the left breast pocket gave the best estimation of the effective male dose (equivalent) although from the measurement it was shown that the same location had the worst angular horizontal response. The study on the effect of skin-dosemeter distance indicated a contradictory result which requires further investigation, whereas the angular vertical response showed less than 10% response variation even for 90o rotation of the dosemeter (author). 11 refs., 2 tabs., 6 figs
Additional details
Publishing Information
- Journal Title
- Atom Indonesia
- Journal Volume
- 21
- Journal Issue
- 1
- Journal Page Range
- p. 9-22.
- ISSN
- 0126-1568
- CODEN
- ATINDD
INIS
- Country of Publication
- Indonesia
- Country of Input or Organization
- Indonesia
- INIS RN
- 26076752
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY;
- Descriptors DEI
- BODY AREAS; CALCULATION METHODS; CESIUM 137; DOSE EQUIVALENTS; DOSE-RESPONSE RELATIONSHIPS; DOSEMETERS; GAMMA SOURCES; HUMAN FACTORS; MATHEMATICAL MODELS; PERSONNEL DOSIMETRY; SKIN ABSORPTION
- Descriptors DEC
- ABSORPTION; BETA DECAY RADIOISOTOPES; BETA-MINUS DECAY RADIOISOTOPES; BODY; CESIUM ISOTOPES; DOSIMETRY; INTERMEDIATE MASS NUCLEI; ISOTOPES; MEASURING INSTRUMENTS; NUCLEI; ODD-EVEN NUCLEI; RADIATION SOURCES; RADIOISOTOPES; SORPTION; UPTAKE; YEARS LIVING RADIOISOTOPES