Management of water leaks on Tore Supra actively cooled fusion device

Description

Up to now, Tore Supra is the only fusion device fully equipped with actively cooled Plasma Facing Components (PFCs). In case of abnormal events during a plasma discharge, the PFCs could be submitted to a transient high power density (run away electrons) or to a continuous phenomena as local thermal flux induced by trapped suprathermal electrons or ions). It could lead to a degradation of the PFC integrity and in the worst case to a water leak occurrence. Such water leak has important consequence on the tokamak operation that concerns PFCs themselves, monitoring equipment located in the vacuum vessel or connected to the ports as RF antennas, diagnostics or pumping systems. Following successive water leak events (the most important water leak, that occurred in September 2002, is described in the paper), a large feedback experience has been gained on Tore supra since more than 15 years that could be useful to actively cooled next devices as W7X and ITER. (authors)

Availability note (English)

Available from INIS in electronic form

Files

37021948.pdf

Files (181.9 kB)

Name Size Download all
md5:2720badaba9a2ed635c21f4d3f38898c
181.9 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
1 p.
Report number
INIS-FR--3986

Conference

Title
9. European vacuum conference
Dates
5-7 Apr 2005
Place
Paris (France)

INIS

Country of Publication
France
Country of Input or Organization
France
INIS RN
37021948
Subject category
S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
FAILURES; FIRST WALL; LEAKS; REPAIR; THERMONUCLEAR REACTOR COOLING SYSTEMS; TORE SUPRA TOKAMAK
Descriptors DEC
CLOSED PLASMA DEVICES; COOLING SYSTEMS; ENERGY SYSTEMS; THERMONUCLEAR DEVICES; THERMONUCLEAR REACTOR WALLS; TOKAMAK DEVICES