Published 1989 | Version v1
Book

Assessment of RELAP/MOD2 using large break loss-of-coolant experimental data

  • 1. Inst. of Nuclear Energy Research, P.O. Box 3-3, Lung-Tan, Tao-Yuan (Taiwan)

Description

In this paper assessment of RELAP5/MOD2 using LOFT L2-5 and Semiscale S-06-3 tests are performed to provide information of the code capability and its limitation in analyzing large break LOCA of a nuclear power plant. Experiments L2-5 and S-06-3 are conducted to simulate a hypothetical LOCA which results from a 200% double-ended offset shear break in the cold-leg of a typical pressurized water reactor by utilizing scaling facilities of the LOFT and Semiscale Mod-1 systems, respectively. The RELAP5/MOD2 calculations for both tests begin with break initiation and subsequent blowdown, continue through lower plenum refill, core reflood, and terminate with corewide quench. Major phenomena of both large break loss-of-coolant tests are well predicted by RELAP5/MOD2. The results indicate that the break flow and system pressure are reasonably calculated. The cladding temperature response during blowdown period, which is the major importance to a large break LOCA, calculated by RELAP5/MOD2 shows good agreement with the test data

Additional details

Publishing Information

Publisher
American Nuclear Society.
Imprint Place
La Grange Park, IL (United States)
ISBN
0-89448-150-9
Imprint Title
Proceedings of the fifth nuclear thermal hydraulics
Imprint Pagination
492 p.
Journal Page Range
p. 202-209.

Conference

Title
Winter meeting of the American Nuclear Society (ANS) and nuclear power and technology exhibit.
Dates
26-30 Nov 1989.
Place
San Francisco, CA (United States).

Optional Information

Secondary number(s)
CONF-891103--.