SNM monitor applications: diversion safeguards for emergency exits and detection of undeclared feed in enrichment plants

Description

A new monitor for special nuclear material (SNM) uses wide plastic scintillators and digital logic to achieve a higher sensitivity for detecting uranium than is found in conventional personnel SNM monitors. With its detectors spaced 2 m apart, the new monitor meets the DOE requirement to detect a 10-g metal 235U sphere of 93% 235U whose total mass is 10.8 g. This capability suits the monitor to scan people who may have to pass quickly through emergency exits. In yet another application, the monitor meets detection goals for detecting freshly separated, natural UF6 that is brought into enrichment plants through personnel portals. To determine the performance of the new monitor for these applications, laboratory source scans and measurements of the growth of uranium daughter activity in freshly separated UF6 were used

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS., PC A02/MF A01 as DE82015038.