Published 1988 | Version v1
Miscellaneous Open

Application of computer code ALMOD 3W2 in nonsymmetric transient analysis in the primary loop of nuclear power plant

  • 1. Elektrotehnicki institut 'rade Koncar', Zagreb (Yugoslavia)
  • 2. Elektrotehnicki fakultet, Zagreb (Yugoslavia)

Description

In this paper the method to calculate the nonsymetric transients in the nuclear power plant is presented. ALMOD 3W2 computer code with steam generator model GEVAP is applied to analyze partial loss of forced reactor coolant flow for NPP Krsko. (author)

Availability note (English)

Available from INIS in electronic form; Also available from the Institute of Nuclear Sciences VINCA

Files

38013843.pdf

Files (192.6 kB)

Name Size Download all
md5:0c5a19fa40f656b1bc70f5cbfd1d77b9
192.6 kB Preview Download

Additional details

Additional titles

Original title (Croatian)
Primjena programa ALMOD 3W2 u analizi nesimetricnih prijelaznih pojava u primarnom krugu nuklearne elektrane

Publishing Information

Publisher
Society for Electronics,Telecommunications, Automation, and Nuclear Engineering
Imprint Place
Belgrade (Yugoslavia)
Imprint Pagination
8 p.
Report number
INIS-RS--0541

Conference

Title
Society for Electronics, Telecommunications, Computers, Automation, and Nuclear Engineering
Original Conference Title
ETAN '88: 32. Konferencija za elektroniku, telekomunikacije, automatiku i nuklearnu tehniku
Acronym
32. Conference - ETRAN '88
Dates
6-10 Jun 1988
Place
Sarajevo (Yugoslavia)

Optional Information

Notes
4 refs., 8 figs.