Published February 1985 | Version v1
Journal article

A low energy antineutron detector

  • 1. Univ. di Torino, Torino

Description

A detector for antineutrons in the momentum range 0.1 - 1 Gev/c, to be used at LEAR faci= lity at CERN, is described. The antineutrons are detected by means of the charged pions produced in an annihilation event and their energy is determined by a time of flight measurement. The detector consists of 10 equal modules; each one contains: an iron slab (the converter) of 20x20x1 cm3, a scintillator of the same dimensions for T.O.F. measurements, an iron sheet of 100x100x0.2 cm3 that stops the low energy high ionizing particles and finally a plane of limited streamer tubes with 1 cm pitch and read-out on both horizontal and vertical coordinates. Principal features of the detector are: T.O.F. resolution of 0.5 ns, spatial resolution of 1 cm in both vertical and horizontal directions, estimated efficien= cy of 0.65

Additional details

Publishing Information

Journal Title
IEEE Trans. Nucl. Sci.
Journal Volume
NS-32
Journal Issue
1
Series
IEEE Trans. Nucl. Sci.
Journal Page Range
733-735
ISSN
0018-9499
CODEN
IETNA

Conference

Title
Nuclear science symposium.
Dates
31 Oct - 2 Nov 1984.
Place
Orlando, FL (USA).

Optional Information

Secondary number(s)
CONF-841007--.