Published 1992 | Version v1
Report Open

Pressure measurements in the AGS Booster ultra-high vacuum system

Description

An average pressure of mid 10-11 Torr has been achieved and maintained in the AGS Booster ring vacuum system during its first year of operation. This ultra-high vacuum system is monitored through remote controlled Bayard-Alpert Gauges (BAGs). The characteristics of the pressure measurements with BAGs over the long cable lengths (up to 200 m) and under various accelerator operating conditions will be described. Two types of noise in the pressure readouts have been identified; the electromagnetic interference (EMI) associated with the acceleration cycles of the Booster and the environment noise associated with the temperature of the collector cables. The magnitude of the noise pickup depends on the routing of the collector cables and reaches the equivalent pressure of low 10-9 Torr

Availability note (English)

MF available from INIS under the Report Number; OSTI as DE93000378; NTIS; INIS; US Govt. Printing Office Dep.

Files

24019440.pdf

Files (283.6 kB)

Name Size Download all
md5:0c3944ba81c8a234a4ded280646b8979
283.6 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
16 p.
Report number
BNL--47348

Conference

Title
12. international vacuum congress; 8. international conference on solid surfaces.
Dates
12-16 Oct 1992; 12-16 Oct 1992.
Place
Hague (Netherlands); Hague (Netherlands).

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
24019440
Subject category
S43: PARTICLE ACCELERATORS;
Resource subtype / Literary indicator
Conference
Descriptors DEI
BROOKHAVEN AGS; PARTICLE BOOSTERS; PERFORMANCE; PRESSURE MEASUREMENT; VACUUM SYSTEMS
Descriptors DEC
ACCELERATORS; CYCLIC ACCELERATORS; SYNCHROTRONS

Optional Information

Contract/Grant/Project number
Contract AC02-76CH00016
Funding organization
USDOE, Washington, DC (United States).
Secondary number(s)
CONF-9210161--4; CONF-9210162--3.