Published May 1995 | Version v1
Journal article

Noninvasive measurement of cerebral blood flow and glucose metabolic rate in the rat with high-resolution animal positron emission tomography (PET). A novel in vivo approach for assessing drug action in the brains of small animals

  • 1. Kyoto Univ. (Japan). Faculty of Medicine

Description

The cerebral metabolic rate of glucose (CMRglc) and cerebral blood flow (CBF) in rats were estimated noninvasively with a high-resolution animal positron emission tomography (PET) system that we recently developed. Quantifications of CMRglc and CBF were attempted with radiotracers, 18F-2-fluoro-2-deoxy-glucose and 15O-water, respectively. From the data obtained with PET, the CMRglc and CBF values under pretreatment conditions were respectively calculated as 51±14 μmol/min/100 g and 61±7 ml/min/100 g under pentobarbital-anesthesia. These values were in close agreement with published data obtained with the autoradiographic technique. Moreover, an increase of 69% (mean) in CBF was detected after i.v. acetazolamide administration. The results indicate that this high-resolution animal PET scanner holds great potential for the assessment of drug-related metabolic and circulatory effects in infact and experimental animals. (author)

Additional details

Publishing Information

Journal Title
Biological and Pharmaceutical Bulletin
Journal Volume
18
Journal Issue
5
Journal Page Range
p. 753-756.
ISSN
0918-6158
CODEN
BPBLEO