Reducing contrast medium volume and tube voltage in CT angiography of the pulmonary artery
- 1. Department of Radiology, Jeroen Bosch Hospital, Henri Dunantstraat 1, 5223 GZ's-Hertogenbosch (Netherlands)
- 2. University of Twente, MIRA-Institute for Biomedical Technology and Technical Medicine P.O. Box 21 7500 AE Enschede (Netherlands)
Description
Aim: To evaluate image quality after contrast medium (CM) and tube voltage reduction in computed tomography angiography (CTA) of the pulmonary artery. Materials and methods: Thirty-three patients referred for CTA of the pulmonary artery for suspected pulmonary embolism were included. Patients were randomly assigned to Protocol I (100 ml of 350 mg iodine/ml iodinated CM; n=16) or Protocol II (50 ml of 350 mg iodine/ml iodinated CM; n=17). Dual-energy CT (80 kV and 140 kV) was performed in all patients. An averaged weighted series equivalent to a 120 kV image acquisition was reconstructed. The mean attenuation value of CM was measured at eight positions in the pulmonary trunk and pulmonary arteries. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Qualitative assessment of the vascular enhancement was performed independently by two experienced radiologists using a three-point scale. Mean attenuation values, image noise, CNR, and SNR of images with 50 ml CM and images with 100 ml CM were compared and mean attenuation values, image noise, CNR, and SNR in 80 kV images and 120 kV images were compared. For qualitative analysis, interobserver variability was analysed using Cohen's kappa statistics. Results: The mean attenuation values in Protocol I and Protocol II were not significantly different at 80 kV (634.6±168.3 versus 537.9±146.7 HU; p=0.088) and 120 kV (482.8±127.7 versus 410.4±106.0 HU; p=0.085). The mean attenuation value at 80 kV was significantly higher than the mean attenuation value at 120 kV in Protocols I and II (p<0.001). The CNR and SNR were higher at 120 kV than at 80 kV in both protocols (p=0.000–0.019); however, there were no significant differences in the CNR and SNR between both protocols (p=0.600–0.952). Qualitative (subjective) analysis showed no statistical significant difference between Protocols I and II (p=0.524–1.000). Conclusion: Low tube voltage (80 kV) CTA using 50 ml CM is not inferior to CTA at 120 kV using 100 ml CM. - Highlights: • Adequate contrast enhancement can be realized with a contrast medium volume reduction of 50%. • There are no significant difference in image quality at 80 kV or 120 kV. • CTA of the pulmonary artery with 50 mL contrast at 80 kV is not inferior to 100 mL at 120 kV.
Availability note (English)
Available from http://dx.doi.org/10.1016/j.crad.2016.03.005Additional details
Identifiers
- DOI
- 10.1016/j.crad.2016.03.005;
- PII
- S0009-9260(16)00121-5;
Publishing Information
- Journal Title
- Clinical Radiology
- Journal Volume
- 71
- Journal Issue
- 6
- Journal Page Range
- p. 615.e7-615.e13
- ISSN
- 0009-9260
- CODEN
- CLRAAG
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 48034274
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ARTERIES; BIOMEDICAL RADIOGRAPHY; COMPUTERIZED TOMOGRAPHY; CONTRAST MEDIA; IMAGES; PATIENTS; SIGNAL-TO-NOISE RATIO
- Descriptors DEC
- BLOOD VESSELS; BODY; CARDIOVASCULAR SYSTEM; DIAGNOSTIC TECHNIQUES; DIMENSIONLESS NUMBERS; MEDICINE; NUCLEAR MEDICINE; ORGANS; RADIOLOGY; TOMOGRAPHY
Optional Information
- Copyright
- Copyright (c) 2016 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.