Objective: To evaluate the feasibility and safety of the clinical application of active fixation electrode in right ventricular outflow tract septum pacing. Methods: One hundred and eighteen patients with indication of pacing were studied. Among whom, 40 had sino-atria node syndrome and 78 atrio-ventricular block. All patients were undertaken an active fixation electrode positioned on right ventricular outflow tract septum for pacing. Results: All 118 cases passed successfully through the procedure, with success rate of 98.3% in localization of the electrode at the right ventricular outflow tract septum accompanied by reaching the standardized pace parameters. The adverse incidences included 1 ease of electrode perforation during the procedure, 2 cases of dislocation afterwords (1.7%). Conclusions: The clinical application of active fixation electrode for fight ventricular outflow tract septum pacing is feasible and safety. (authors)
Additional details
Publishing Information
- Journal Title
- Journal of Interventional Radiology
- Journal Volume
- 17
- Journal Issue
- 4
- Journal Page Range
- p. 231-233
- ISSN
- 1008-794X
INIS
- Country of Publication
- China
- Country of Input or Organization
- China
- INIS RN
- 41073547
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- CARDIOVASCULAR DISEASES; ELECTRODES; HEART; PATIENTS; PERFORATION; SAFETY; THERAPY
- Descriptors DEC
- BODY; CARDIOVASCULAR SYSTEM; DISEASES; MEDICINE; ORGANS
Optional Information
- Notes
- 1 fig., 1 tab., 8 refs.