Use of GTE-65 gas turbine power units in the thermal configuration of steam-gas systems for the refitting of operating thermal electric power plants

  • 1. 'Leningradskii Metallicheskii Zavod', branch of JSC 'Silovye mashiny' (Russian Federation)
  • 2. 'Institut Teploenergoproekt', branch of JSC 'Inzhenernyi tsentr EES' (Russian Federation)

Description

Thermal configurations for condensation, district heating, and discharge steam-gas systems (PGU) based on the GTE-65 gas turbine power unit are described. A comparative multivariant analysis of their thermodynamic efficiency is made. Based on some representative examples, it is shown that steam-gas systems with the GTE-65 and boiler-utilizer units can be effectively used and installed in existing main buildings during technical refitting of operating thermal electric power plants

Additional details

Identifiers

Publishing Information

Journal Title
Power Technology and Engineering (Print)
Journal Volume
42
Journal Issue
4
Journal Page Range
p. 236-246
ISSN
1570-145X

INIS

Country of Publication
United States
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
40107532
Subject category
S42: ENGINEERING;
Descriptors DEI
BOILERS; CONFIGURATION; DISTRICT HEATING; EFFICIENCY; ELECTRIC POWER; GAS TURBINES; STEAM; THERMODYNAMICS
Descriptors DEC
EQUIPMENT; HEATING; MACHINERY; POWER; TURBINES; TURBOMACHINERY

Optional Information

Copyright
Copyright (c) 2008 Springer Science+Business Media, Inc.
Notes