Published January 2003 | Version v1
Journal article

Application of SSNTD for neutron monitoring

  • 1. Defence Laboratory, Jodhpur (India)

Description

CR-39 is the most sensitive detector for neutron monitoring and dosimetry applications but its dose equivalent response is strongly direction dependent with respect to the incident neutrons. This is considered to be a major drawback for their use. In the present study, an attempt has been made to develop a pyramid shaped dosimeter, which consists of polyethylene material of thickness 1 mm with the provision to hold three CR-39 films at an angle of 35 deg to each other. The response of CR-39 in this configuration under optimum electrochemical etching at elevated temperature have been found nearly angular independent and can be used for neutron monitoring i.e. personnel as well as area monitoring. (author)

Additional details

Publishing Information

Journal Title
Radiation Protection and Environment
Journal Volume
26
Journal Issue
1-2,pt.1
Journal Page Range
p. 46-50
CODEN
RPREFM

Conference

Title
26. IARP conference on radiation exposure control at nuclear fuel cycle facilities and radiation installations
Acronym
IARP-NC.2K3
Dates
5-7 Mar 2003
Place
Kalpakkam (India)

Optional Information

Notes
12 refs., 7 figs., 2 tabs.