Diagnostic accuracy and utility of coronary CT angiography with consideration of unevaluable results: A systematic review and multivariate Bayesian random-effects meta-analysis with intention to diagnose
Creators
- 1. University Medical Center Goettingen, Institute for Diagnostic and Interventional Radiology, Goettingen (Germany)
- 2. Dr. Lauterbach-Klinik, Department of Cardiology, Bad Liebenstein (Germany)
Description
To meta-analyze diagnostic accuracy, test yield and utility of coronary computed tomography angiography (CCTA) in coronary artery disease (CAD) by an intention-to-diagnose approach with inclusion of unevaluable results. Four databases were searched from 1/2005 to 3/2013 for prospective studies that used 16-320-row or dual-source CTs and provided 3 x 2 patient-level data of CCTA (positive, negative, or unevaluable) versus catheter angiography (positive or negative) for diagnosing ≥50 % coronary stenoses. A Bayesian multivariate 3 x 2 random-effects meta-analysis considered unevaluable CCTAs. Thirty studies (3422 patients) were included. Compared to 16-40 row CT, test yield and accuracy of CCTA has significantly increased with ≥64-row CT (P < 0.05). In ≥64-row CT, about 2.5 % (95 %-CI, 0.9-4.8 %) of diseased patients and 7.5 % (4.5-11.2 %) of non-diseased patients had unevaluable CCTAs. A positive likelihood ratio of 8.9 (6.1-13.5) indicated moderate suitability for identifying CAD. A negative likelihood ratio of 0.022 (0.01-0.04) indicated excellent suitability for excluding CAD. Unevaluable CCTAs had an equivocal likelihood ratio of 0.42 (0.22-0.71). In the utility analysis, CCTA was useful at intermediate pre-test probabilities (16-70 %). CCTA is useful at intermediate CAD pre-test probabilities. Positive CCTAs require verification to confirm CAD, unevaluable CCTAs require alternative diagnostics, and negative CCTAs exclude obstructive CAD with high certainty. (orig.)
Availability note (English)
Available from: http://dx.doi.org/10.1007/s00330-015-3831-zAdditional details
Identifiers
Publishing Information
- Journal Title
- European Radiology
- Journal Volume
- 26
- Journal Issue
- 2
- Journal Page Range
- p. 451-458
- ISSN
- 0938-7994
- CODEN
- EURAE3
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 47024308
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ACCURACY; COMPUTERIZED TOMOGRAPHY; CORONARIES; DIAGNOSTIC USES; DISEASE INCIDENCE; EFFICIENCY; MORTALITY; MULTIVARIATE ANALYSIS; PROBABILITY; QUALITY ASSURANCE; SENSITIVITY; SPECIFICITY; VASCULAR DISEASES
- Descriptors DEC
- ARTERIES; BLOOD VESSELS; BODY; CARDIOVASCULAR DISEASES; CARDIOVASCULAR SYSTEM; DIAGNOSTIC TECHNIQUES; DISEASES; MATHEMATICS; ORGANS; STATISTICS; TOMOGRAPHY; USES