Published December 1, 2011 | Version v1
Journal article

Test beam results of Current Injected Detectors (CID) irradiated up to 5×1015 1 MeV neq/cm2

  • 1. Helsinki Institute of Physics, Gustaf Hällströmin Katu 2, P.O. Box 64, University of Helsinki, 00014 Helsinki (Finland)
  • 2. Ioffe Physical Technical Institute, St. Petersburg (Russian Federation)
  • 3. Fermi National Laboratory, Batavia (United States)
  • 4. University of Freiburg, Freiburg (Germany)

Description

Two full size strip detectors were investigated in this study: one with p+ strips (p+/n-/n+) and another with n+ strips (n+/p-/p+). Both detectors, are made of magnetic Czochralski silicon (MCz-Si) and irradiated to S-LHC fluencies, were tested with 225 GeV muon beam in the CERN H2 area. The Current Injected Detector (CID) sensors were operated in a cooling box capable of providing a -53 °C temperature. Results indicate a relative charge collection efficiency (CCE) at 5×1015 neq/cm2 above 30% in irradiated p+/n-/n+ CID detector at 600 V bias voltage. The signal to noise ratio of this CID module was about eight and a forward current of 30 μA was needed for detector biasing. In standard reverse bias, the same detector could not provide a sufficiently large signal for particle tracking purposes. A p-type (n+/p-/p+) sensor was irradiated to a fluence of 2×1015 neq/cm2 and measured under the same test beam conditions. According to the theory of CIDs developed by the CERN RD39 Collaboration, this detector module could be biased up to only 230 V due to the low irradiation fluence. The CCE at 230 V was 35% in CID operation and 20% when reverse biased.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.nima.2011.06.076

Additional details

Identifiers

DOI
10.1016/j.nima.2011.06.076;
PII
S0168-9002(11)01245-9;

Publishing Information

Journal Title
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
Journal Volume
658
Journal Issue
1
Journal Page Range
p. 51-54
ISSN
0168-9002
CODEN
NIMAER

Conference

Title
8. international conference on radiation effects on semiconductor materials, detectors and devices
Acronym
RESMDD 2010
Dates
12-15 Oct 2010
Place
Florence (Italy)

Optional Information

Copyright
Copyright (c) 2011 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.