SMART 2013: Experimental and numerical assessment of the dynamic behavior by shaking table tests of an asymmetrical reinforced concrete structure subjected to high intensity ground motions
Creators
- 1. CEA, DEN, DANS, DM2S, SEMT, Laboratoire d'Etudes de Mecanique Sismique, F-91191 Gif-sur-Yvette, (France)
- 2. Institute of Mechanical Sciences and Industrial Applications, EDF-CNRS-CEA-ENSTA UMR 9219, 1, avenue du General de Gaulle, F-92141 Clamart, (France)
- 3. EDF, DR and D, Acoustics and Mechanical Analysis Department, 1, avenue du General de Gaulle, F-92141 Clamart, (France)
- 4. EDF, SEPTEN, Dynamic and Earthquake Engineering Group, 12-14, avenue Dutrievoz, F-69628 Villeurbanne, (France)
Description
As part of a large research program launched and funded by the French Atomic Energy and Sustainable Energies Commission (CEA) and Electricite De France (EDF), partially supported by the International Atomic Energy Agency (IAEA) and entitled 'Seismic design and best-estimate Methods Assessment for Reinforced concrete buildings subjected to Torsion and nonlinear effect (SMART)', a series of shaking table tests on a 1/4-scale 3-story reinforced concrete model characterized by a strong asymmetry has been carried out in July 2013. The seismic loading was composed of three test sequences having different peak ground accelerations (PGA): the design level signal (PGA equal to 0.2 g), the North ridge main shock signal (PGA equal to 1.78 g) and a North ridge aftershock (PGA equal to 0.33 g). In this paper, the main experimental results, compared with outputs from a numerical study carried out by CEA, are presented and discussed. The following conclusions were reached for each seismic test sequence: (i) only small nonlinearities appeared and both displacement and acceleration-based quantities were properly estimated by the model; (ii) the specimen exhibited moderate nonlinearities in case of PGA higher than 4 or 5 times the design PGA; displacements were numerically underestimated whereas maximum acceleration-based quantities were captured rather well; (iii) the fact that no additional damage was monitored during this seismic sequence was pointed out only by the experimental measurements but also by the numerical outputs, leading to show that this aftershock signal did not induce any further damage. Given the aforementioned observations, it was possible to carry out a robustness analysis based upon two damage indicators: the eigenfrequency shift and the inter-story drift. Apart from the issues of the most meaningful robustness indicator and the choice of damage thresholds that came up, it is shown that the specimen can be qualified as being robust. (authors)
Availability note (English)
Available from doi: http://dx.doi.org/10.1016/j.engstruct.2015.11.029Additional details
Identifiers
Publishing Information
- Journal Title
- Engineering Structures
- Journal Volume
- 109
- Journal Page Range
- p. 99-116
- ISSN
- 0141-0296
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- France
- INIS RN
- 50033305
- Subject category
- S71: CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSICS;
- Descriptors DEI
- ASYMMETRY; GROUND MOTION; NONLINEAR PROBLEMS; REINFORCED CONCRETE; SEISMIC EFFECTS; TORSION
- Descriptors DEC
- BUILDING MATERIALS; COMPOSITE MATERIALS; CONCRETES; MATERIALS; MOTION; REINFORCED MATERIALS
Optional Information
- Notes
- 50 refs.