Published August 10, 2007 | Version v1
Journal article

Power Transmission From The ITER Model Negative Ion Source

  • 1. Association EURATOM-DCU, PRL/NCPST, Glasnevin, Dublin 13 (Ireland)
  • 2. Association EURATOM-CEA, CEA/DSM/DRFC, CEA-Cadarache, 13108 St Paul-Lez-Durance (France)

Description

In Cadarache development on negative ion sources is being carried out on the KAMABOKO III ion source on the MANTIS test bed. This is a model of the ion source designed for the neutral beam injectors of ITER. This ion source has been developed in collaboration with JAERI, Japan, who also designed and supplied the ion source. Its target performance is to accelerate a D- beam, with a current density of 200 A/m2 and <1 electron extracted per accelerated D- ion, at a source filling pressure of 0.3 Pa. For ITER a continuous ion beam must be assured for pulse lengths of 1000 s, but beams of up to 3,600 s are also envisaged. The ion source is attached to a 3 grid 30 keV accelerator (also supplied by JAERI) and the accelerated negative ion current is determined from the energy deposited on a calorimeter. During long pulse operation (≤1000 s) it was found that the current density of both D- and H- beams, measured at the calorimeter was lower than expected and that a large discrepancy existed between the accelerated currents measured electrically and those transmitted to the calorimeter. The possibility that this discrepancy arose because the accelerated current included electrons (which would not be able to reach the calorimeter) was investigated and subsequently eliminated. Further studies have shown that the fraction of the electrical current reaching the calorimeter varies with the pulse length, which led to the suggestion that one or more of the accelerator grids were distorting due to the incident power during operation, leading to a progressive deterioration in the beam quality.. New extraction and acceleration grids have been designed and installed, which should have a better tolerance to thermal loads than those previously used. This paper describes the measurements of the power transmission and distribution using these grids

Additional details

Identifiers

Publishing Information

Journal Title
AIP Conference Proceedings
Journal Volume
925
Journal Issue
1
Journal Page Range
p. 238-248
ISSN
0094-243X
CODEN
APCPCS

Conference

Title
11. international symposium on the production and neutralization of negative ions and beams
Dates
13-15 Sep 2006
Place
Santa Fe, NM (United States)

INIS

Optional Information

Notes
(c) 2007 American Institute of Physics