Published September 2011 | Version v1
Journal article

Evaluation of dose to tooth enamel from medical diagnostic X-ray examinations at Mayak PA

  • 1. Helmholtz Zentrum Muenchen - German Research Center for Environmental Health, Institute of Radiation Protection, D-85764 Neuherberg (Germany)
  • 2. Mayak Production Association, 456780 Ozyorsk (Russian Federation)

Description

The nuclear workers of the Mayak Production Association had regular check-ups including medical diagnostic X-ray examinations since start of the production lines in 1948. Doses from diagnostic examinations need to be considered in reconstruction of occupational doses of the workers with electron paramagnetic resonance (EPR) of tooth enamel. The numbers and types of examinations of an individual worker can be assessed from the Mayak PA archives but no information was available on doses delivered to teeth by a single specific examination. Of the twenty one applied examination procedures only three affected the teeth, these being X-ray examinations of teeth, skull and cervical spine. For these three kinds of examinations operational procedures and operating modes of X-ray units were compiled from the archive and photon spectra were obtained from a catalog of spectral data for diagnostic X-rays. Entrance doses in air kerma were calculated using the fluence of photon spectra and absorbed dose in tooth enamel for various tooth positions and exposure geometry was then calculated using dose conversion coefficients obtained from Monte Carlo simulations. Doses were calculated for examinations in 1948-2000. Except for examination of the skull, absorbed doses in enamel of incisors were found to be about twice as large as in enamel of molars. In the period before 1970 the largest mean absorbed doses in tooth enamel were due to X-ray examination of teeth, with 64 mGy and 34 mGy calculated for incisors and molars, respectively. In the same period the lowest mean doses were due to X-ray examination of the skull, with 11 mGy and 12 mGy calculated for incisors and molars, respectively. In the period from 1970 to 2000, largest mean doses in enamel were due to X-ray examination of cervical spine, with 23 mGy and 12 mGy calculated for incisors and molars, respectively.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.radmeas.2011.03.010

Additional details

Identifiers

DOI
10.1016/j.radmeas.2011.03.010;
PII
S1350-4487(11)00081-3;

Publishing Information

Journal Title
Radiation Measurements
Journal Volume
46
Journal Issue
9
Journal Page Range
p. 808-812
ISSN
1350-4487
CODEN
RMEAEP

Conference

Title
EPRBioDose 2010 international conference
Dates
11-14 Oct 2010
Place
Mandelieu-la-Napoule (France)

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
43064677
Subject category
S61: RADIATION PROTECTION AND DOSIMETRY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
COMPUTERIZED SIMULATION; ELECTRON SPIN RESONANCE; ENAMELS; EVALUATION; MONTE CARLO METHOD; RADIATION DOSES; SKULL; TEETH; X RADIATION
Descriptors DEC
BODY; CALCULATION METHODS; COATINGS; DIGESTIVE SYSTEM; DOSES; ELECTROMAGNETIC RADIATION; IONIZING RADIATIONS; MAGNETIC RESONANCE; ORAL CAVITY; ORGANS; RADIATIONS; RESONANCE; SIMULATION; SKELETON

Optional Information

Copyright
Copyright (c) 2011 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.