Published 1999 | Version v1
Journal article

Development of Two-Dosemeter Algorithm for Better Estimation of Effective Dose Equivalent and Effective Dose

Description

An optimal algorithm, which suitably combines two dosemeter readings, one dosemeter on the chest and the other on the back, for better estimation of effective dose equivalent (HE) and effective dose (E), was developed by utilising hundreds of broad parallel photon beam irradiation geometries. The developed algorithm, weighting front (chest) and back dosemeter readings by 0.58 and 0.42, respectively, was found to be superior to other currently available algorithms, neither underestimating HE or E by more than 14%, nor overestimating by more than a few tens of a per cent for a broad range of frontal and dorsal incident beams. Like other algorithms, however, this algorithm tends to overestimate HE and E significantly for the lateral, overhead and underfoot beam directions. This study also suggests that this overestimation problem significantly decreases when one uses typical commercial dosemeters instead of isotropic-responding dosemeters. (author)

Additional details

Publishing Information

Journal Title
Radiation Protection Dosimetry
Journal Volume
81
Journal Issue
2
Journal Page Range
p. 101-112
ISSN
0144-8420
CODEN
RPDODE

INIS

Country of Publication
United Kingdom
Country of Input or Organization
Ecuador
INIS RN
31050487
Subject category
S61: RADIATION PROTECTION AND DOSIMETRY;
Descriptors DEI
ALGORITHMS; CHEST; DOSE EQUIVALENTS; DOSEMETERS; DOSIMETRY; PHOTON BEAMS; RADIATION DOSES; THERMOLUMINESCENT DOSEMETERS
Descriptors DEC
BEAMS; BODY; DOSEMETERS; DOSES; LUMINESCENT DOSEMETERS; MEASURING INSTRUMENTS