Published April 2016
| Version v1
Journal article
Monte-Carlo simulation of cryopanel parameter in CYCIAE-100 cyclotron
- 1. China Institute of Atomic Energy, Beijing (China)
Description
The gas molecular collision model was built based on the theory of gas molecular motion, and structure parameters such as sticking probability and transmission rate of cryopanel placed in the magnet valley of CYCIAE-100 cyclotron were simulated by Monte-Carlo method. The pumping speed of cryopanel was tested in testing dome. The results show that the pumping speed of cryopanel simulated by Monte-Carlo method is consistent with test results, and the relative error is 2%. (authors)
Additional details
Identifiers
Publishing Information
- Journal Title
- Atomic Energy Science and Technology
- Journal Volume
- 50
- Journal Issue
- 4
- Journal Page Range
- p. 737-740
- ISSN
- 1000-6931
INIS
- Country of Publication
- China
- Country of Input or Organization
- China
- INIS RN
- 50021052
- Subject category
- S43: PARTICLE ACCELERATORS;
- Descriptors DEI
- COLLISIONS; COMPUTERIZED SIMULATION; CYCLOTRONS; ERRORS; MONTE CARLO METHOD; TEMPERATURE RANGE 0065-0273 K; TRANSMISSION; VELOCITY
- Descriptors DEC
- ACCELERATORS; CALCULATION METHODS; CYCLIC ACCELERATORS; SIMULATION; TEMPERATURE RANGE
Optional Information
- Notes
- 5 figs., 1 tab., 12 refs.; http://dx.doi.org/10.7538/yzk.2016.50.04.0737