Published April 2016 | Version v1
Journal article

Monte-Carlo simulation of cryopanel parameter in CYCIAE-100 cyclotron

  • 1. China Institute of Atomic Energy, Beijing (China)

Description

The gas molecular collision model was built based on the theory of gas molecular motion, and structure parameters such as sticking probability and transmission rate of cryopanel placed in the magnet valley of CYCIAE-100 cyclotron were simulated by Monte-Carlo method. The pumping speed of cryopanel was tested in testing dome. The results show that the pumping speed of cryopanel simulated by Monte-Carlo method is consistent with test results, and the relative error is 2%. (authors)

Additional details

Identifiers

Publishing Information

Journal Title
Atomic Energy Science and Technology
Journal Volume
50
Journal Issue
4
Journal Page Range
p. 737-740
ISSN
1000-6931

INIS

Country of Publication
China
Country of Input or Organization
China
INIS RN
50021052
Subject category
S43: PARTICLE ACCELERATORS;
Descriptors DEI
COLLISIONS; COMPUTERIZED SIMULATION; CYCLOTRONS; ERRORS; MONTE CARLO METHOD; TEMPERATURE RANGE 0065-0273 K; TRANSMISSION; VELOCITY
Descriptors DEC
ACCELERATORS; CALCULATION METHODS; CYCLIC ACCELERATORS; SIMULATION; TEMPERATURE RANGE

Optional Information

Notes
5 figs., 1 tab., 12 refs.; http://dx.doi.org/10.7538/yzk.2016.50.04.0737