Published November 2013 | Version v1
Journal article

Cathode fall measurement in a dielectric barrier discharge in helium

  • 1. School of Electric Power, South China University of Technology, Guangzhou 510640 (China)

Description

A method based on the "zero-length voltage" extrapolation is proposed to measure cathode fall in a dielectric barrier discharge. Starting, stable, and discharge-maintaining voltages were measured to obtain the extrapolation zero-length voltage. Under our experimental conditions, the "zero-length voltage" gave a cathode fall of about 185 V. Based on the known thickness of the cathode fall region, the spatial distribution of the electric field strength in dielectric barrier discharge in atmospheric helium is determined. The strong cathode fall with a maximum field value of approximately 9.25 kV/cm was typical for the glow mode of the discharge

Additional details

Identifiers

Publishing Information

Journal Title
Physics of Plasmas
Journal Volume
20
Journal Issue
11
Journal Page Range
p. 113510-113510.4
ISSN
1070-664X
CODEN
PHPAEN

Optional Information

Notes
(c) 2013 AIP Publishing LLC