Published September 1991 | Version v1
Journal article

Electrochemical exposure rack test results

  • 1. Corrosion Failure Analysis and Control, San Ramon, CA (United States)
  • 2. Florida Power Corp., St. Petersburg, FL (United States)

Description

This paper reports that severe corrosion was detected in the circulating water system of Florida Power Corporation's Crystal River Unit 3 nuclear power plant. An independent study determined that the attack on the type 304L (UNS S30403) stainless steel pipes and condenser water boxes was caused by exposure to untreated seawater from the Gulf of Mexico and microbiologically influenced corrosion (MIC). Testing was performed to evaluate galvanic corrosion on coupled samples and determine cathodic protection criteria and effectiveness on four materials in an untreated seawater cooling system with microbiologically influenced corrosion. Tests were also conducted to evaluate possible hydrogen embrittlement of cathodically protected condenser tube materials considered for retubing

Additional details

Additional titles

Subtitle (English)
Crystal River Nuclear Power Plant

Publishing Information

Journal Title
Materials Performance
Journal Volume
30
Journal Issue
9
Series
Mater. Performance.
Journal Page Range
18-24
ISSN
0094-1492
CODEN
MTPFB