The research to compare the sensitivity of TLD-100H (LiF:Mg,Cu,P) with OSLD nanoDot (Al2O3:C) to be used in medical applications on low dose monitoring has been carried out. Before use, the dosimeter must be annealed using heat for TLD-100H and intensity light for OSLD nanoDot . The reading process of dosimeter responses uses heat stimulation for TLD and optical stimulation for OSLD. The purpose of this study was to obtain the dosimeters with high sensitivity for monitoring of low doses received by patients, so that the data will becomes more accurate. The calibrated TLD-100H used has a response with deviation <3%. Dosimeters has exposed on phantom surface with energy and doses variations using X-ray and Cs-137 at Secondary Standard Dosimetry Laboratory of PTKMR BATAN. The results of study showing that the response of OSLD nanoDot exposed to gamma ray and X-rays with doses greater than 2 mSv lower from response of TLD-100H. Conversely, for doses smaller than 2 mSv the OSLD response is higher than TLD-100H. To measure the low-dose of patients in medical physics, OSLD nanoDot are a better choice than TLD-100H. Another advantage, OSLD nanoDot can be readed directly after receiving radiation exposure and can be repeatedly without significantly affecting dose value. (author)

Files

50062907.pdf

Files (435.3 kB)

Name Size Download all
md5:4d9eebb5ed3e2cae118e82260a388b04
435.3 kB Preview Download
Part of:
Proceedings of the 2018 National Nuclear Technology Human Resources Seminar

Additional details

Additional titles

Original title (Indonesian)
Perbandingan sensitivitas TLD-100H (LiF:Mg,Cu,P) dan OSLD NanoDot (Al2O3:C) dalam aplikasi medis pemantauan dosis rendah

Publishing Information

Publisher
Polytechnic Institute of Nuclear Technology, National Nuclear Energy Agency
Imprint Place
Yogyakarta (Indonesia)
Imprint Title
Proceedings of the 2018 National Nuclear Technology Human Resources Seminar
Imprint Pagination
528 p.
Journal Page Range
p. 512-517
ISSN
1978-0176
Report number
INIS-ID--88

Conference

Title
Human Resource Innovation & Nuclear Science and Technology to Support the Industrial Revolution 4.0
Original Conference Title
Inovasi SDM & Iptek Nuklir untuk Mendukung Revolusi Industri 4.0
Dates
20 Aug 2018
Place
Yogyakarta (Indonesia)

Optional Information

Notes
18 refs.; 1 tab.; 3 figs. Imprint:Prosiding Seminar Nasional SDM Teknologi Nuklir 2018