Evaluation of horizontal cooling channels for actively cooled limiters

  • 1. Sandia National Labs., Albuquerque, NM 87185

Description

The heat flux and fluid flow conditions for a water cooled limiter tube are simulated with an electron beam heating apparatus, and the results are compared to empirical models based on existing heating transfer correlations. For the conditions of highly subcooled flow boiling in a horizontal tube subjected to a heat flux from only one side, two principal observations were noted. First, existing heat flux correlations, which were developed for use with uniform circumferential heat flux distributions, can be used to provide a good first approximation of the one-sided heat removal for the range of experimental conditions covered. Second, the peak heat flux at the tube surface predicts the onset of critical heat flux (burnout) better than the average heat flux

Additional details

Publishing Information

Journal Title
Fusion Technol.
Journal Volume
10
Journal Issue
3
Series
Fusion Technol.
Journal Page Range
789-796
ISSN
0748-1896
CODEN
FUSTE

Conference

Title
7. topical meeting on the technology of fusion energy.
Dates
15-19 Jun 1986.
Place
Reno, NV (USA).

Optional Information

Secondary number(s)
CONF-860652--.