Published 1989 | Version v1
Book

The beam profile measurement system at the Bates linac

  • 1. MIT Bates Linear Accelerator Center, Middleton, MA (USA)

Description

A linac beam profile measurement system using wire scanners has been implemented at the Bates Linear Accelerator Center. This facilitates obtaining an optimum linac focusing solution. A nearly non-invasive beam size measurement is made of the two beams which are accelerated simultaneously in the recirculating linac. The wire scanner mechanical accuracy is near one mil. Beam size measurements are reproducible to a few mils. 4 refs., 7 figs

Additional details

Publishing Information

Publisher
Institute of Electrical and Electronics Engineers.
Imprint Place
New York, NY (USA)
Imprint Title
Proceedings of the 1989 IEEE (Institute of Electrical and Electronics Engineers) particle accelerator conference. Volume 3
Imprint Pagination
678 p.
Journal Page Range
p. 1523-1525.

Conference

Title
1989 IEEE particle accelerator conference.
Dates
20-23 Mar 1989.
Place
Chicago, IL (USA).

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
21058996
Subject category
S43: PARTICLE ACCELERATORS;
Resource subtype / Literary indicator
Conference
Descriptors DEI
APERTURES; BEAM MONITORS; BEAM PROFILES; BEAM SCANNERS; COMPUTERIZED SIMULATION; DISTANCE; LINEAR ACCELERATORS; PERFORMANCE; REAL TIME SYSTEMS; SIZE; TUNING
Descriptors DEC
ACCELERATORS; MEASURING INSTRUMENTS; MONITORS; OPENINGS; SIMULATION

Optional Information

Secondary number(s)
CONF-890335--Vol.3.