Published May 11, 2005 | Version v1
Journal article

Event-synchronized data acquisition system for the SPring-8 linac beam position monitors

  • 1. SPring-8, 1-1-1, Kouto, Mikazuki, Soyo-gun, Hyogo 679-5198 (Japan)

Description

By the summer of 2003, we had completed the installation of a new non-destructive beam position monitor (BPM) system to facilitate beam trajectory and energy correction for the SPring-8 linac. In all, 47 BPM sets were installed on the 1-GeV linac and three beam-transport lines. All of the BPM data acquisition system was required to operate synchronously with the electron beam acceleration cycle. We have developed an event-synchronized data acquisition system for the BPM data readout. We have succeeded in continuously taking all the BPMs data from six VME computers synchronized with the 10 pps operation of the linac to continuously acquire data. For each beam shot, the data points are indexed by event number and stored in a database. Using the real-time features of the Solaris operating system and distributed database technology, we currently have achieved about 99.9% efficiency in capturing and archiving all of the 10 Hz data. The linac BPM data is available for off-line analysis of the beam trajectory, but also for real-time control and automatic correction of the beam trajectory and energy

Additional details

Identifiers

DOI
10.1016/j.nima.2004.12.025;
PII
S0168-9002(05)00042-2;

Publishing Information

Journal Title
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
Journal Volume
543
Journal Issue
2-3
Journal Page Range
p. 415-430
ISSN
0168-9002
CODEN
NIMAER

Optional Information

Copyright
Copyright (c) 2005 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.