Published 1987 | Version v1
Miscellaneous

Chernobyl safety lessons for the CANDU system

Creators

  • 1. Atomic Energy of Canada Ltd., Sheridan Park, ON (Canada). CANDU Operations

Description

Although the reactor types are very different, so that a Chernobyl-type accident is impossible in a CANDU reactor, nevertheless, CANDU designers have learned the following lessons from Chernobyl: 1) To conduct a more fundamental review of possible flux shapes in the core of CANDU reactors, and then to determine the effectiveness of each of the two shutdown systems in relation to these flux shapes; 2) To review the use of interlocks, key switches, etc.; 3) To review fire safety with special attention to any radiation hazards that may impede fire fighting

Part of:
Proceedings of the 27. annual conference of the Canadian Nuclear Association

Additional details

Additional titles

Subtitle (English)
A designer's perspective

Publishing Information

Imprint Title
Proceedings of the 27. annual conference of the Canadian Nuclear Association
Imprint Pagination
398 p.
Journal Page Range
p. 267-271.
Report number
INIS-mf--13673

Conference

Title
27. Annual conference of the Canadian Nuclear Association.
Dates
14-17 Jun 1987.
Place
Saint John, NB (Canada).

Optional Information