As required by different international agreements, the regulatory body in Spain (Consejo de Seguridad Nuclear) implemented in 1992 a national automatic network (REVIRA) that continuously monitors radiation levels in order to give early warning of incidents having potential transboundary implications. The detector for environmental gamma radiation dose rate is an active instrument based on a Geiger-Mueller counter. However, the use of passive environmental dosemeters provides an additional low-cost dose estimate with an independent centralised calibration and even better basic features than active instruments. Since 1999, all 25 REVIRA stations have been monitored with passive TL environmental dosemeters based on LiF:Mg,Cu,P and operated according to the procedures established at Ciemat. This paper presents the obtained results and the further analysis considering differences in aspects such as photon energy response, inherent background or response to cosmic rays. The benefits of the use of passive environmental dosemeters in early warning networks are discussed. (author)