Effects of filters on the performance and characteristics of pressure-sensitive paints
Creators
- 1. School of MACE, University of Manchester, Manchester M60 1QD (United Kingdom)
Description
The current study investigates the effect of four different filter combinations on the pressure sensitivity, signal level and temperature sensitivity of pressure-sensitive paint (PSP) samples in an a priori calibration. Two different PSP formulations developed at the Aero-Physics Laboratory are studied, one using hydrochloric acid (PSP1-HCl) and the other acetone (PSP2-Ace). Both are incorporated in a sol–gel solution. The results show that the effect of choosing different bandwidths, central wavelengths and transmissions of the filters for the emitted and excitation wavelengths can have a significant impact on the behaviour of PSP, luminescent signal level, pressure and temperature sensitivity, and also eliminate the undesired wavelengths which can affect the final results. (technical design note)
Availability note (English)
Available from http://dx.doi.org/10.1088/0957-0233/20/7/077004Additional details
Identifiers
- DOI
- 10.1088/0957-0233/20/7/077004;
- PII
- S0957-0233(09)11131-1;
Publishing Information
- Journal Title
- Measurement Science and Technology
- Journal Volume
- 20
- Journal Issue
- 7
- Journal Page Range
- [6 p.]
- ISSN
- 0957-0233
- CODEN
- MSTCEP
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 45005561
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- ACETONE; DESIGN; EXCITATION; FILTERS; HYDROCHLORIC ACID; LUMINESCENCE; PAINTS; SENSITIVITY; SIGNALS; SOLUTIONS; WAVELENGTHS
- Descriptors DEC
- CHLORINE COMPOUNDS; COATINGS; DISPERSIONS; EMISSION; ENERGY-LEVEL TRANSITIONS; HALOGEN COMPOUNDS; HOMOGENEOUS MIXTURES; HYDROGEN COMPOUNDS; INORGANIC ACIDS; INORGANIC COMPOUNDS; KETONES; MIXTURES; ORGANIC COMPOUNDS; PHOTON EMISSION