Published October 1, 1983 | Version v1
Journal article

A comparison of methods for determining neutron detector efficiencies at medium energies

  • 1. Kent State Univ., OH (USA). Dept. of Physics
  • 2. Indiana Univ., Bloomington (USA). Cyclotron Facility

Description

We compare the 'Lithium Activation' (LiA) method and the 'Isospin Clebsch-Gordan Ratio' (ICGR) method for determining detection efficiencies of neutrons between 100 and 160 MeV. Each method was used to determine the efficiency by relating a measured neutron yield to a cross section measured in another way: γ-ray activation cross sections for LiA; (p, p') cross sections from experiments at the Indiana University Cyclotron Facility for ICGR. Efficiencies determined by the two methods disagree substantially. Efficiencies calculated with the Monte Carlo code of Cecil et al. agree with the ICGR results. We conclude that the Lithium Activation method is inconsistent at these energies. (orig.)

Additional details

Publishing Information

Journal Title
Nucl. Instrum. Methods Phys. Res.
Journal Volume
215
Journal Issue
3
Series
Nucl. Instrum. Methods Phys. Res.
Journal Page Range
413-421
ISSN
0167-5087

Optional Information

Contract/Grant/Project number
Contract PHY-79-07790; PHY-82-00562; PHY-78-22774; PHY-81-14339
Notes
With 38 refs.