Published May 2012
| Version v1
Journal article
Technical analysis of digital measurement in AP1000 control rods
Description
It analyzes the control rods, CRDM and rod position measurement detector layout based on AP1000 digital rod position system. At the same time, the application of high reliability technologies in AP1000, such as non-contact sensor measurements, the redundant design of detection coil and digital data transmission, which can ensure the accuracy of rod position measurement and the safety and reliability of control system in AP1000. (authors)
Additional details
Publishing Information
- Journal Title
- Nuclear Electronics and Detection Technology
- Journal Volume
- 32
- Journal Issue
- 5
- Journal Page Range
- p. 627-630
- ISSN
- 0258-0934
INIS
- Country of Publication
- China
- Country of Input or Organization
- China
- INIS RN
- 49053814
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- ACCURACY; CONTROL ELEMENTS; CONTROL SYSTEMS; DATA TRANSMISSION; DESIGN; DETECTION; PWR TYPE REACTORS; RELIABILITY; RODS; SAFETY; SENSORS
- Descriptors DEC
- COMMUNICATIONS; ENRICHED URANIUM REACTORS; POWER REACTORS; REACTOR COMPONENTS; REACTORS; THERMAL REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS
Optional Information
- Notes
- 4 figs., 1 tab., 5 refs.