Published November 1984 | Version v1
Journal article

Uranium-235 measurement in waste material by resonance neutron radiography

Creators

  • 1. National Bureau of Standards, Washington, D.C. 20234

Description

The use of resonance neutron radiography as a means of monitoring the amount of 235U in waste material is investigated. A matrix material simulating incinerator ash is inoculated with 235U in concentrations ranging from 4.8 X 10-4 to 4.6 X 10 3 g/cm3. The observed uncertainty agrees well with an analytical model and ranges from 16% for the lowest concentration to 2.5% for the highest concentration. The effect of inhomogeneity of matrix and sample is determined and found to be in agreement with analytical models. The technique is demonstrated on sample sizes ranging from 2-l bottles to 55-gal drums

Additional details

Publishing Information

Journal Title
Nucl. Technol.
Journal Volume
67
Journal Issue
2
Series
Nucl. Technol.
Journal Page Range
326-332
ISSN
0029-5450