Published November 1984
| Version v1
Journal article
Uranium-235 measurement in waste material by resonance neutron radiography
Description
The use of resonance neutron radiography as a means of monitoring the amount of 235U in waste material is investigated. A matrix material simulating incinerator ash is inoculated with 235U in concentrations ranging from 4.8 X 10-4 to 4.6 X 10 3 g/cm3. The observed uncertainty agrees well with an analytical model and ranges from 16% for the lowest concentration to 2.5% for the highest concentration. The effect of inhomogeneity of matrix and sample is determined and found to be in agreement with analytical models. The technique is demonstrated on sample sizes ranging from 2-l bottles to 55-gal drums
Additional details
Publishing Information
- Journal Title
- Nucl. Technol.
- Journal Volume
- 67
- Journal Issue
- 2
- Series
- Nucl. Technol.
- Journal Page Range
- 326-332
- ISSN
- 0029-5450
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 16057519
- Subject category
- S54: ENVIRONMENTAL SCIENCES;
- Descriptors DEI
- HETEROGENEOUS EFFECTS; MATHEMATICAL MODELS; MATRICES; NEUTRON RADIOGRAPHY; QUANTITY RATIO; RADIOACTIVE WASTES; SIMULATION; URANIUM 235
- Descriptors DEC
- ACTINIDE NUCLEI; ALPHA DECAY RADIOISOTOPES; EVEN-ODD NUCLEI; HEAVY NUCLEI; ISOMERIC TRANSITION ISOTOPES; ISOTOPES; MATERIALS; MINUTES LIVING RADIOISOTOPES; NUCLEI; RADIOACTIVE MATERIALS; RADIOISOTOPES; URANIUM ISOTOPES; WASTES; YEARS LIVING RADIOISOTOPES