Coincidence corrections for a multi-detector gamma spectrometer
- 1. AWE, Aldermaston, Reading, Berkshire RG7 4PR (United Kingdom)
- 2. University of Surrey, Guildford GU2 7XH (United Kingdom)
Description
List-mode data acquisition has been utilised in conjunction with a high-efficiency γ–γ coincidence system, allowing both the energetic and temporal information to be retained for each recorded event. Collected data is re-processed multiple times to extract any coincidence information from the γ-spectroscopy system, correct for the time-walk of low-energy events, and remove accidental coincidences from the projected coincidence spectra. The time-walk correction has resulted in a reduction in the width of the coincidence delay gate of 18.4±0.4%, and thus an equivalent removal of ‘background’ coincidences. The correction factors applied to ∼5.6% of events up to ∼500 keV for a combined 137Cs and 60Co source, and are crucial for accurate coincidence measurements of low-energy events that may otherwise be missed by a standard delay gate. By extracting both the delay gate and a representative ‘background’ region for the coincidences, a coincidence background subtracted spectrum is projected from the coincidence matrix, which effectively removes ∼100% of the accidental coincidences (up to 16.6±0.7% of the total coincidence events seen during this work). This accidental-coincidence removal is crucial for accurate characterisation of the events seen in coincidence systems, as without this correction false coincidence signatures may be incorrectly interpreted
Availability note (English)
Available from http://dx.doi.org/10.1016/j.nima.2014.09.054Additional details
Identifiers
- DOI
- 10.1016/j.nima.2014.09.054;
- PII
- S0168-9002(14)01082-1;
Publishing Information
- Journal Title
- Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
- Journal Volume
- 769
- Journal Page Range
- p. 20-25
- ISSN
- 0168-9002
- CODEN
- NIMAER
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 46125448
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- CESIUM 137; COBALT 60; COINCIDENCE SPECTROMETRY; CORRECTIONS; DATA ACQUISITION; EFFICIENCY; GAMMA SPECTROMETERS; GAMMA SPECTROSCOPY; KEV RANGE 100-1000; RADIATION DETECTORS; REMOVAL; SPECTRA; WIDTH
- Descriptors DEC
- BETA DECAY RADIOISOTOPES; BETA-MINUS DECAY RADIOISOTOPES; CESIUM ISOTOPES; COBALT ISOTOPES; COINCIDENCE METHODS; COUNTING TECHNIQUES; DATA PROCESSING; DIMENSIONS; ENERGY RANGE; INTERMEDIATE MASS NUCLEI; INTERNAL CONVERSION RADIOISOTOPES; ISOMERIC TRANSITION ISOTOPES; ISOTOPES; KEV RANGE; MEASURING INSTRUMENTS; MINUTES LIVING RADIOISOTOPES; NUCLEI; ODD-EVEN NUCLEI; ODD-ODD NUCLEI; PROCESSING; RADIOISOTOPES; SPECTROMETERS; SPECTROSCOPY; YEARS LIVING RADIOISOTOPES
Optional Information
- Copyright
- Copyright (c) 2014 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.