Nuclear power plant alarm systems: Problems and issues
Description
Despite the incorporation of advanced technology into nuclear power plant alarm systems, human factors problems remain. This paper identifies to be addressed in order to allow advanced technology to be used effectively in the design of nuclear power plant alarm systems. The operator's use and processing of alarm system information will be considered. Based upon a review of alarm system research, issues related to general system design, alarm processing, display and control are discussed. It is concluded that the design of effective alarm systems depends on an understanding of the information processing capabilities and limitations of the operator. 39 refs
Availability note (English)
MF available from INIS under the Report Number; OSTI as DE91014843; NTIS; INIS; US Govt. Printing Office Dep.Files
22091143.pdf
Files
(244.8 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:9ef1c960c1611efd9a32b207b1d080c4
|
244.8 kB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- 5 p.
- Report number
- BNL-NUREG--46262
Conference
- Title
- Human Factors Society (HFS) conference.
- Dates
- 2-6 Sep 1991.
- Place
- San Francisco, CA (USA).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 22091143
- Subject category
- S22: GENERAL STUDIES OF NUCLEAR REACTORS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- ALARM SYSTEMS; HUMAN FACTORS; INFORMATION; NUCLEAR POWER PLANTS; SPECIFICATIONS
- Descriptors DEC
- NUCLEAR FACILITIES; POWER PLANTS; THERMAL POWER PLANTS
Optional Information
- Contract/Grant/Project number
- Contract AC02-76CH00016
- Funding organization
- USDOE, Washington, DC (USA).
- Secondary number(s)
- CONF-9109160--2.