1989 neutron and gamma personnel dosimetry intercomparison study using RADCAL [Radiation Calibration Laboratory] sources
- 1. Oak Ridge National Lab., TN (USA)
- 2. Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Dept. of Health Physics
- 3. Stanford Linear Accelerator Center, Menlo Park, CA (USA)
Description
The fourteenth Personnel Dosimetry Intercomparison Study (i.e., PDIS 14) was conducted during May 1-5, 1989. A total of 48 organizations (33 from the US and 15 from abroad) participated in PDIS 14. Participants submitted by mail a total of 1,302 neutron and gamma dosimeters for this mixed field study. The type of neutron dosimeter and the percentage of participants submitting that type are as follows: TLD-albedo (40%), direct interaction TLD (22%), track (20%), film (7%), combination (7%), and bubble detectors (4%). The type of gamma dosimeter and the percentage of participants submitting that type are as follows: TLD (84%) and film (16%). Radiation sources used in the six PDIS 14 exposures included 252Cf moderated by 15-cm D2O, 252Cf moderated by 15-cm polyethylene (gamma-enhanced with 137Cs), and 238PuBe. Neutron dose equivalents ranged from 0.44--2.63 mSv and gamma doses ranged from 0. 01-1.85 mSv. One 252Cf(D2O) exposure was performed at a 60 degree angle of incidence (most performance tests are at perpendicular incidence). The average neutron dosimeter response for this exposure was 70% of that at normal incidence. The average gamma dosimeter response was 96% of that at normal incidence. A total of 70% of individual reported neutron dosimeter measurements were within ±50% of reference values. If the 0.01 mSv data are omitted, approximately 90% of the individual reported gamma measurements were within ±50% of reference values. 33 refs., 9 figs., 27 tabs
Availability note (English)
MF available from INIS under the Report Number; OSTI as DE91004978; NTIS; INIS; US Govt. Printing Office Dep.Files
22038497.pdf
Files
(1.5 MB)
| Name | Size | Download all |
|---|---|---|
|
md5:bd1379368c2e7d3d2f54e0d384bf6164
|
1.5 MB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- 71 p.
- Report number
- ORNL--6597
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 22038497
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- CALIFORNIUM 252; CESIUM 137; COMPARATIVE EVALUATIONS; DOSE EQUIVALENTS; DOSEMETERS; GAMMA DOSIMETRY; GAMMA SOURCES; NEUTRON DOSIMETRY; NEUTRON SOURCES; PERFORMANCE TESTING; PERSONNEL DOSIMETRY; PHOTOGRAPHIC FILM DOSEMETERS; THERMOLUMINESCENT DOSEMETERS
- Descriptors DEC
- ACTINIDE NUCLEI; ALPHA DECAY RADIOISOTOPES; BETA DECAY RADIOISOTOPES; BETA-MINUS DECAY RADIOISOTOPES; CALIFORNIUM ISOTOPES; CESIUM ISOTOPES; DOSIMETRY; EVALUATION; EVEN-EVEN NUCLEI; HEAVY NUCLEI; INTERMEDIATE MASS NUCLEI; ISOTOPES; LUMINESCENT DOSEMETERS; MEASURING INSTRUMENTS; NUCLEI; ODD-EVEN NUCLEI; PARTICLE SOURCES; RADIATION SOURCES; RADIOISOTOPES; SPONTANEOUS FISSION RADIOISOTO; TESTING; YEARS LIVING RADIOISOTOPES
Optional Information
- Contract/Grant/Project number
- Contract AC05-84OR21400