Published September 23, 2011 | Version v1
Journal article

Effective doses to family members of patients treated with radioiodine-131

  • 1. Institute of Pathophysiology and Nuclear Medicine, Medical Faculty, University of 'Sts Cyril and Methodius', Skopje (Macedonia, The Former Yugoslav Republic of)
  • 2. Technical Faculties, University of Novi Sad (Serbia)

Description

The purpose of this study was to evaluate the effective dose to family members of thyroid cancer and hyperthyroid patients treated with radioiodine-131, and also to compare the results with dose constraints proposed by the International Commission of Radiological Protection (ICRP) and the Basic Safety Standards (BSS) of the International Atomic Energy Agency (IAEA). For the estimation of the effective doses, sixty family members of sixty patients, treated with radioiodine-131, and thermoluminiscent dosimeters (Model TLD 100) were used. Thyroid cancer patients were hospitalized for three days, while hyperthyroid patients were treated on out-patient basis. The family members wore TLD in front of the torso for seven days. The radiation doses to family members of thyroid cancer patients were well below the recommended dose constraint of 1 mSv. The mean value of effective dose was 0.21 mSv (min 0.02 - max 0.51 mSv). Effective doses, higher than 1 mSv, were detected for 11 family members of hyperthyroid patients. The mean value of effective dose of family members of hyperthyroid patients was 0.87 mSv (min 0.12 - max 6.79). The estimated effective doses to family members of hyperthyroid patients were higher than the effective doses to family members of thyroid carcinoma patients. These findings may be considered when establishing new national guidelines concerning radiation protection and release of patients after a treatment with radioiodine therapy.

Availability note (English)

Available from http://dx.doi.org/10.1088/1742-6596/317/1/012012

Additional details

Publishing Information

Journal Title
Journal of Physics. Conference Series (Online)
Journal Volume
317
Journal Issue
1
Journal Page Range
[6 p.]
ISSN
1742-6596

Conference

Title
International Conference on Image Optimisation in Nuclear Medicine (OptiNM)
Dates
23-26 Mar 2011
Place
Ayia Napa (Cyprus)

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
43081864
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Resource subtype / Literary indicator
Conference
Descriptors DEI
CARCINOMAS; COMPARATIVE EVALUATIONS; PATIENTS; RADIATION DOSES; RADIATION PROTECTION; RADIOTHERAPY; THERMOLUMINESCENT DOSIMETRY; THYROID
Descriptors DEC
BODY; DISEASES; DOSES; DOSIMETRY; ENDOCRINE GLANDS; EVALUATION; GLANDS; MEDICINE; NEOPLASMS; NUCLEAR MEDICINE; ORGANS; RADIOLOGY; THERAPY