Comparison of Computed Tomography and Cineangiography in the Demonstration of Central Pulmonary Arteries in Cyanotic Congenital Heart Disease
- 1. Department of Cardiovascular Radiology, C.T. Centre, All India Institute of Medical Sciences, Ansari Nagar, New Delhi-110 029 (India)
- 2. Department of Cardiology, C.T. Centre, All India Institute of Medical Sciences, Ansari Nagar, New Delhi-110 029 (India)
Description
Purpose: To assess the diagnostic accuracy of contrast-enhanced computed tomography (CT) for central pulmonary artery pathology in patients with cyanotic congenital heart disease (CCHD) and right ventricular outflow obstruction. Methods: We compared contrast-enhanced CT and cine pulmonary arteriography in 24 patients with CCHD to assess central pulmonary arteries including the confluence. Both investigations were interpreted by a cardiac radiologist in a double-blinded manner at an interval of 3 weeks. Angiography was used as the gold standard for comparison. Results: The sensitivity for visualization of main pulmonary artery (MPA), right pulmonary artery (RPA), left pulmonary artery (LPA), and confluence on CT was 94%, 100%, 92.8%, and 92.8%, respectively. Diagnostic specificity for the same entities was 28.5%, 100%, 80%, and 50%, respectively. The positive predictive value for each was 76.2%, 100%, 94.1%, and 72.2%, respectively. The low specificity of CT in the evaluation of the MPA and the confluence is perhaps due to distorted right ventricular outflow anatomy in CCHD. Large aortopulmonary collaterals in this region were mistaken for the MPA in some patients with pulmonary atresia. Conclusion: CT is a useful, relatively noninvasive, imaging technique for the central pulmonary arteries in selected patients. It can supplement diagnostic information from angiography but cannot replace it. LPA demonstration on axial images alone is inadequate
Additional details
Identifiers
Publishing Information
- Journal Title
- Cardiovascular and Interventional Radiology
- Journal Volume
- 19
- Journal Issue
- 2
- Journal Page Range
- p. 97-100
- ISSN
- 0174-1551
- CODEN
- CAIRDG
INIS
- Country of Publication
- United States
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 39093218
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ACCURACY; ANATOMY; ARTERIES; BIOMEDICAL RADIOGRAPHY; CARDIOVASCULAR DISEASES; COMPUTERIZED TOMOGRAPHY; IMAGES; PATHOLOGY; PATIENTS; SPECIFICITY
- Descriptors DEC
- BIOLOGY; BLOOD VESSELS; BODY; CARDIOVASCULAR SYSTEM; DIAGNOSTIC TECHNIQUES; DISEASES; MEDICINE; NUCLEAR MEDICINE; ORGANS; RADIOLOGY; TOMOGRAPHY
Optional Information
- Copyright
- Copyright (c) 1996 Springer-Verlag New York Inc.