The procedure problems and solution of CT-guided percutaneous biopsy of spinal diseases
Creators
- 1. Department of Radiology, Zhangzhou Tranditional Chinese Medical Hosptial, Fujian (China)
Description
Objective: To discuss the procedural problems and solution correlatively of CT-guided percutaneous biopsy of spinal diseases, with simultaneous evaluation of the safety and clinical application. Methods: Sixty-eight cases with spinal diseases were taken CT-guided percutaneous biopsy under local anesthesia and CT guidance, including 9 in cervical spine, 19 in thoracic spine, 28 in lumbar spine and 12 in sacral spine. The program of carrying out the procedure was decided according to the site, approach route of the lesion with the destination of sampling, under CT guidance. Results: The successful rate of needle puncture was 100%(68/68)with diagnostic accuracy of 92.6%(63/68), and false-negative rate of 7.4%(5/ 68), together with complications rate of 5.9% (4/68). Conclusions: CT-guided vertebral biopsy is safe, reliable, less complication, high accuracy and together with clear demonstration of the position of puncture needle and the complex anatomic structures nearby, providing basic information for further clinical treatment and worthy to be recommended. (authors)
Additional details
Publishing Information
- Journal Title
- Journal of Interventional Radiology
- Journal Volume
- 17
- Journal Issue
- 7
- Journal Page Range
- p. 518-521
- ISSN
- 1008-794X
INIS
- Country of Publication
- China
- Country of Input or Organization
- China
- INIS RN
- 41076295
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ACCURACY; ANESTHESIA; BIOPSY; CAT SCANNING; DIAGNOSIS; EVALUATION; MEDICAL SURVEILLANCE; SAFETY; VERTEBRAE
- Descriptors DEC
- BODY; COMPUTERIZED TOMOGRAPHY; DIAGNOSTIC TECHNIQUES; ORGANS; SKELETON; TOMOGRAPHY
Optional Information
- Notes
- 13 refs.