Hypothetical accident conditions, free drop and thermal tests: Specification 6M

Description

The 30 gallon Specification 6M shipping container with rolled-top food pack cans as inner containers is evaluated under conditions required by 10 CFR 71.42. One kilogram of depleted uranium as UO2 was packaged in each of the inner containers. After completion of a free drop test and a simulated thermal test, the maximum observed leakage of UO2 for the following week was 3.2 μg. This leakage is well below the allowable leakage per week for most plutonium isotopic mixtures. Using the examples provided, any plutonium isotopic mixture can be easily compared with the allowable leakage per week. Test conditions and results are reported

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS., PC A02/MF A01.

Files

11559259.pdf

Files (357.3 kB)

Name Size Download all
md5:f2971bc4b55c331d987a81354d2ce930
357.3 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
15 p.
Report number
LA--8366-MS