Published 2004 | Version v1
Miscellaneous

Post-irradiation examinations of the irradiated HANARO instrumented capsule(02M-02K) in IMEF

  • 1. Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

Description

The PIEs such a transportation, visual inspection, cut and dismantling, specimen classification including neutron monitors are carrying out for the instrumented capsule 02M-02K irradiated at CT test hole of HANARO during 6 days with 144 MWD in IMEF (Irradiation Materials Examination Facility) from the beginning of September, 2004. The neutron fluence of this capsule is predicted to 3.4 x 1019 n/cm2 (E>1.0 MeV) assumed to the amount of the lifetime of nuclear reactor. This capsule consists of 5 specimen holders and contains several kinds of specimens- Charpy specimens, PCVN, small tensile specimens, 1/3 size Cv specimens, and small punch specimens- with neutron monitors to research and develop the advanced material characteristics of reactor material. The capsule was cut during 1 hour with Al2O3 cutting wheel under condition for chuck in 2.5 rpm, for wheel in 200 rpm with 0.15 mm/min feed. The PIE process is described in detail in this paper

Part of:
Proceedings of the KNS autumn meeting

Additional details

Publishing Information

Publisher
KNS
Imprint Place
Taejon (Korea, Republic of)
Imprint Title
Proceedings of the KNS autumn meeting
Imprint Pagination
1466 p.
Journal Page Range
p. 951-952

Conference

Title
2004 autumn meeting of the KNS
Dates
28-29 Oct 2004
Place
Yongpyong (Korea, Republic of)

Optional Information

Notes
4 refs, 3 figs, 1 tab