Cobalt source calibration

Description

The data obtained from these tests determine the dose rate of the two cobalt sources in SRTC. Building 774-A houses one of these sources while the other resides in room C-067 of Building 773-A. The data from this experiment shows the following: (1) The dose rate of the No.2 cobalt source in Building 774-A measured 1.073 x 105 rad/h (June 17, 1999). The dose rate of the Shepherd Model 109 Gamma cobalt source in Building 773-A measured 9.27 x 105 rad/h (June 25, 1999). These rates come from placing the graduated cylinder containing the dosimeter solution in the center of the irradiation chamber. (2) Two calibration tests in the 774-A source placed the graduated cylinder with the dosimeter solution approximately 1.5 inches off center in the axial direction. This movement of the sample reduced the measured dose rate 0.92% from 1.083 x 105 rad/h to 1.073 x 105 rad/h. and (3) A similar test in the cobalt source in 773-A placed the graduated cylinder approximately 2.0 inches off center in the axial direction. This change in position reduced the measured dose rate by 10.34% from 1.036 x 106 to 9.27 x 105. This testing used chemical dosimetry to measure the dose rate of a radioactive source. In this method, one determines the dose by the chemical change that takes place in the dosimeter. For this calibration experiment, the author used a Fricke (ferrous ammonium sulfate) dosimeter. This solution works well for dose rates to 107 rad/h. During irradiation of the Fricke dosimeter solution the Fe2+ ions ionize to Fe3+. When this occurs, the solution acquires a slightly darker tint (not visible to the human eye). To determine the magnitude of the change in Fe ions, one places the solution in an UV-VIS Spectrophotometer. The UV-VIS Spectrophotometer measures the absorbency of the solution. Dividing the absorbency by the total time (in minutes) of exposure yields the dose rate

Availability note (English)

Available from INIS in electronic form; Also available from OSTI as DE00750095; PURL: https://www.osti.gov/servlets/purl/750095-4pt6yd/webviewable/

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
13 p.
Report number
WSRC-TR--99-00303/Rev.1

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
31034038
Subject category
S07: ISOTOPES AND RADIATION SOURCES;
Descriptors DEI
CALIBRATION; CHEMICAL DOSEMETERS; DOSE RATES; GAMMA SOURCES; POSITIONING
Descriptors DEC
DOSEMETERS; MEASURING INSTRUMENTS; RADIATION SOURCES

Optional Information

Contract/Grant/Project number
AC09-96SR18500
Funding organization
US Department of Energy (United States)