Exoelectron reader
Creators
- 1. CEA Centre d'Etudes Nucleaires de Fontenay-aux-Roses, 92 (France). Dept. de Protection
- 2. Comision Nacional de Energia Atomica, Buenos Aires (Argentina)
Description
Research on exoelectron emission phenomena led on to the study of an exoelectron 'reader'. The measurement system includes a proportional counter supplied by adjustable high tension (3000 volts). The pulses from this counter are transmitted by an impedance adapter preamplifier to a counting scaler and ictometer and the output data recorded as a function of time. The sample temperature variation must be linear with time. It is piloted by a digital method which solves in an original way the linearity and drift problems of analog systems. Heating rates between 0.1 deg C sec-1 and 10 deg C sec-1 are selected from contrave type coding wheels and the heating is governed by a digital-analog converter. The sample temperature variation can be followed from a 'temperature' information output. Furthermore the heating element for the material studied is controlled through a furnace curve correction circuit by which the furnace resistance variation may be corrected as a function of temperature
Abstract (French)
A la suite des etudes effectuees sur les phenomenes d'emission exoelectronique on a ete amene a etudier un lecteur d'exoelectrons. L'ensemble de mesure comprend un compteur proportionnel alimente par une haute tension reglable (3000 volts). Les impulsions issues de ce compteur sont transmises a l'aide d'un preamplificateur adaptateur d'impedance a une echelle de comptage et a un ictometre dont on enregistre les indications en fonction du temps. La variation de temperature de l'echantillon doit etre lineaire en fonction du temps. Elle est pilotee au moyen d'une methode digitale qui permet de resoudre d'une facon originale les problemes de linearite et de derive des systemes analogiques. Les vitesses de chauffage comprises entre 0,1 deg sec-1 et 10 deg sec-1 sont selectionnees a partir de roues codeuses de type 'contraves'. La commande de chauffage est obtenue a l'aide d'un convertisseur digital-analogique. Une sortie de l'information 'temperature' permet de suivre l'evolution de la temperature de l'echantillon. D'autre part, l'element de chauffage du materiau a etudier est commande par l'intermediaire d'un circuit appele correction de la courbe du four qui permet de corriger la variation de la resistance de ce dernier en fonction de la temperatureAdditional details
Additional titles
- Original title (French)
- Lecteur d'exoelectrons
Publishing Information
- Publisher
- Societe Francaise de Radioprotection.
- Imprint Place
- Montrouge, France
- Imprint Title
- Basic and applied aspects of dosimetry
- Imprint Pagination
- p. 364-379.
Conference
- Title
- basic and applied aspects of dosimetry.
- Acronym
- 8. International congress of the French Society for Radiation Protection
- Dates
- 23 Mar 1976.
- Place
- Saclay, France.
INIS
- Country of Publication
- France
- Country of Input or Organization
- France
- INIS RN
- 8310715
- Subject category
- S07: ISOTOPES AND RADIATION SOURCES;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- EXOELECTRON DOSEMETERS; READOUT SYSTEMS
- Descriptors DEC
- DOSEMETERS; MEASURING INSTRUMENTS
Optional Information
- Notes
- Imprint:Aspects fondamentaux et appliques de la dosimetrie.;8. Congres international de la Societe Francaise de Radioprotection. Saclay, France, 23-26 mars 1976.