Published 1984 | Version v1
Journal article

Duct inspection and repair programme for Magnox nuclear power reactors

Creators

  • 1. Central Electricity Generating Board, London (UK)

Description

Details are presented of the inspection, repair, and replacement programmes that were necessary after welding defects had been discovered in primary circuit attachments at three of the Central Electricity Generating Board's (CEGB) steel pressure vesselled stations. These were at Bradwell and Dungeness 'A' power stations in the South Eastern Region of the CEGB and at Berkeley power station in the South Western Region. The refurbishment programme required both nuclear reactors at each station to be shut down for periods of two to three years. (author)

Additional details

Publishing Information

Journal Title
Proc. Inst. Mech. Eng., Part A: Power Process Eng.
Journal Volume
198
Journal Issue
13
Series
Proc. Inst. Mech. Eng., Part A: Power Process Eng.
Journal Page Range
301-307
ISSN
0263-7138

INIS

Country of Publication
United Kingdom
Country of Input or Organization
United Kingdom
INIS RN
16039156
Subject category
S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
Descriptors DEI
BELLOWS; BOILERS; DEFECTS; DUCTS; INSPECTION; MAGNOX TYPE REACTORS; REACTOR MAINTENANCE; REPAIR; WELDED JOINTS
Descriptors DEC
JOINTS; MAINTENANCE; NATURAL URANIUM REACTORS; POWER REACTORS; REACTORS