Published April 1996
| Version v1
Report
Dynamic response to an expected steam hammer of the steam line from steam generator 5 outside the hermetic zone at the Mochovce-1 reactor unit
Description
The response to a steam hammer induced by an abrupt closing of the quick-closing valve was calculated for the segment from the hermetic penetration to the main steam header to the quick-closing valve of turbogenerator 1. The feasibility of occurrence of resonance states of the piping and the strain response of the steam line (shock wave propagation, strain status of the piping) were analyzed. The conditional probability of damage was also determined
Availability note (English)
Available from Nuclear Research Institute Rez, 250 68 Rez, Czech Republic.Additional details
Additional titles
- Original title (Czech)
- Dynamicka odezva potrubi pary z PG5 vne hermeticke zony EMO, blok 1 na ocekavany parni raz
Publishing Information
- Imprint Pagination
- 96 p.
- Report number
- UJV--10662-T
INIS
- Country of Publication
- Czech Republic
- Country of Input or Organization
- Czech Republic
- INIS RN
- 29006827
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Resource subtype / Literary indicator
- Non-conventional Literature
- Descriptors DEI
- DYNAMIC LOADS; MECHANICAL VIBRATIONS; MOCHOVCE-1 REACTOR; SHOCK WAVES; STEAM; STEAM LINES; STRAINS; STRESSES; VALVES
- Descriptors DEC
- CONTROL EQUIPMENT; ENRICHED URANIUM REACTORS; EQUIPMENT; FLOW REGULATORS; PIPELINES; POWER REACTORS; PWR TYPE REACTORS; REACTORS; THERMAL REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS; WWER TYPE REACTORS