Published October 1995 | Version v1
Miscellaneous

Application of the general perturbation theory for a reconstruction of the assemblywise power distribution inside the VVER-440 core

Creators

  • 1. Paksi Atomeroemue Vallalat, Paks (Hungary)

Description

A method is described applying the general perturbation theory to improved calculation of flux or power distribution in the reactor core, using in-core detector signals. The thermometer signals were received from the in-core system in the Paks NPP. The 2D version of code C-PORCA was used. The results show the frequency of occurrence of differences between the reconstructed and the measured assemblywise temperature rise of the coolant water. (J.B.) 2 figs., 6 refs

Part of:
Proceedings of the international topical meeting on VVER safety

Additional details

Publishing Information

Imprint Title
Proceedings of the international topical meeting on VVER safety
Imprint Pagination
416 p.
Journal Page Range
p. 179-182.
Report number
INIS-mf--14715

Conference

Title
International topical meeting on VVER safety.
Dates
21-23 Sep 1995.
Place
Prague (Czech Republic).

Optional Information