Published 2017
| Version v1
Journal article
Measurements of radiation doses in air by thermoluminescence dosimeter in Saitama prefecture before and after Fukushima Dai-ichi Nuclear Power Plant accident. Apr. 2008-Mar. 2014
Creators
- 1. Saitama Prefectural Institute of Public Health, Yoshimi, Saitama (Japan)
Description
Radiation doses in air at 7 points in Saitama Prefecture were measured by thermoluminescence dosimeter from 2008 to 2013. Annual radiation doses at 7 points in 2008 and 2009 were 0.40#approx#0.69 mGy/y and 0.40#approx# 0.68 mGy/y, respectively. These values were similar to those before 2007. However, annual radiation doses in air at all points, except 1 point where the measurement place was changed, increased after 2010. And the value in 2011 was the highest. It was thought that the cause of radiation doses increase was Fukushima Dai-ichi Nuclear Power Plant Accident occurred on Mar. 11, 2011. (author)
Availability note (English)
Available from DOI: https://doi.org/10.3769/radioisotopes.66.35Abstract (Japanese)
2008~2013年度にかけて,TLDを用いて県内7か所の空間放射線量を測定した。年間空間放射線量は,2008年度は0.40~0.69 mGy/年及び2009年度は0.40~0.68 mGy/年であり,2007年度以前の値と同程度であった。2010年度からは測定地点の変更のあった1か所を除く全ての地点で増加がみられ,2011年度に最も高い値を示した。年間空間放射線量が増加した原因については,2011年3 月11日に発生した福島原発事故の影響と推測された。(著者)Additional details
Additional titles
- Original title (Japanese)
- 福島第一原子力発電所事故前後の埼玉県における熱ルミネセンス線量計を用いた空間放射線量の測定.2008~2013年度
Identifiers
Publishing Information
- Journal Title
- Radioisotopes (Online)
- Journal Volume
- 66
- Journal Issue
- 1
- Journal Page Range
- p. 35-41
- ISSN
- 1884-4111
INIS
- Country of Publication
- Japan
- Country of Input or Organization
- Japan
- INIS RN
- 52097649
- Subject category
- S54: ENVIRONMENTAL SCIENCES;
- Descriptors DEI
- CESIUM 137; DOSE LIMITS; DOSE RATES; EFFECTIVE RADIATION DOSES; FUKUSHIMA DAIICHI NUCLEAR POWER STATION; MELTDOWN; NUCLEAR POWER PLANTS; PHOTOLUMINESCENCE; RADIATION MONITORING; THERMOLUMINESCENT DOSEMETERS
- Descriptors DEC
- ACCIDENTS; BETA DECAY RADIOISOTOPES; BETA-MINUS DECAY RADIOISOTOPES; BEYOND-DESIGN-BASIS ACCIDENTS; CESIUM ISOTOPES; DOSEMETERS; DOSES; EMISSION; INTERMEDIATE MASS NUCLEI; ISOTOPES; LUMINESCENCE; LUMINESCENT DOSEMETERS; MEASURING INSTRUMENTS; MONITORING; NUCLEAR FACILITIES; NUCLEI; ODD-EVEN NUCLEI; PHOTON EMISSION; POWER PLANTS; RADIATION DOSES; RADIOISOTOPES; REACTOR ACCIDENTS; REACTOR SITES; SAFETY STANDARDS; SEVERE ACCIDENTS; STANDARDS; THERMAL POWER PLANTS; YEARS LIVING RADIOISOTOPES
Optional Information
- Notes
- 11 refs., 4 figs., 4 tabs.