Published June 1983 | Version v1
Book

Assessment of tracheal obstruction by body plethysmography

  • 1. Muenchen Univ. (Germany, F.R.). Medizinische Klinik Innenstadt

Description

Bodyplethysmography is a Valuable Method to Test Obstructive Disturbances of Ventilation. The Analysis of Bodyplethysmographic Curves Helps to Determine the Bronchial Resistance and to Differentiate upper Airway Stenoses. Examples show the characteristic curves of extra- or intrathoracic, variable or fixed stenoses of the trachea. 71 patients with palpable goiter and dyspnoe have been examined by body-plethysmography and by X-ray to find out stenoses of the trachea, caused by malacia. The X-ray findings of a significant deviation of the tracheal diameter are followed by characteristic disturbances in pulmonary function test in only 30% of the patients. Only pulmonary function studies as a physiological method of testing can select and determine the functional relevant cases of stenoses of the trachea, caused by malacia. (orig.)

Abstract (German)

Die Bodyplethysmographie ist eine wertvolle Methode zur Objektivierung obstruktiver Ventilationsstoerungen. Ueber die Bestimmung des bronchialen Stroemungswiderstandes hinaus dient die Analyse der Druckstroemungskurven zur Differenzierung hochsitzender Atemwegsstenosen. Anhand von Beispielen werden die charakteristischen Kurvenbilder von extra- oder intrathorakal gelegenen, variablen oder fixierten Trachealstenosen erlaeutert. 71 Patienten mit tastbarer Struma und Atemnot werden bodyplethysmographisch und roentgenologisch auf das Vorliegen einer malaziebedingten Trachealeinengung untersucht. Der Roentgenbefund einer signifikanten Tracheallumenschwankung wird nur in 30% der Faelle durch charakteristische Parameter einer Ventilationsbehinderung lungenfunktionsanalytisch bestaetigt. Nur die Lungenfunktionsanalyse ist als physiologische Messmethode geeignet, die funktionell relevanten Befunde einer malaziebedingten Trachealbeeintraechtigung zu selektieren und quantitativ einzustufen. (orig.)

Additional details

Additional titles

Subtitle (English)
A comparison of dynamic functional analysis and static X-ray diagnosis
Original title (German)
Die Beurteilung der Trachealbeeintraechtigung durch die Bodyplethysmographie
Original subtitle (German)
Ein Vergleich von dynamischer Funktionsanalyse und statischer Roentgendiagnostik.

Publishing Information

Publisher
Thieme.
Imprint Place
Stuttgart (Germany, F.R.)
Imprint Title
Imaging techniques in thyroid diagnostics
Imprint Pagination
154 p.
Journal Volume
4
Journal Issue
1
Series
Aktuelle Endokrinologie und Stoffwechsel. Sonderheft.
Journal Page Range
p. 10-14.

Conference

Title
Meeting of the Deutsche Gesellschaft fuer Endokrinologie (Sektion Schilddruese).
Dates
26-27 Nov 1982.
Place
Luebeck (Germany, F.R.).

INIS

Country of Publication
Germany
Country of Input or Organization
Germany
INIS RN
15056249
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Resource subtype / Literary indicator
Conference
Descriptors DEI
BIOLOGICAL FUNCTIONS; BIOMEDICAL RADIOGRAPHY; DIAGNOSIS; IMAGES; PATIENTS; RESPIRATORY SYSTEM DISEASES; TRACHEA; VENTILATION; X RADIATION
Descriptors DEC
DIAGNOSTIC TECHNIQUES; DISEASES; ELECTROMAGNETIC RADIATION; IONIZING RADIATIONS; MEDICINE; RADIATIONS; RESPIRATORY SYSTEM

Optional Information

Notes
Imprint:Bildgebende Verfahren in der Schilddruesendiagnostik.;Diskussionsunterlagen.